BOLTON GILXAN MANUFACTURING
Ultra-narrow aluminium sliding door with large glazing
Performance & quality

Performance, stated in the right language.

Five criteria Catalogue figures · report on request
01 / Performance

A performance figure belongs to a build-up, not a brochure.

Wind, water, air, sound and heat are decided by profile, glass, hardware, seals and installation together.

The values below are catalogue figures for the named systems. Final performance depends on size, glazing build-up, fixing detail and the test standard of the destination market — so every project is confirmed against an approved shop drawing and, where required, a model test report.

We do not display certification marks we have not obtained. If your market requires SABER, CE, AS or NFRC documentation, state the standard at enquiry stage and we will confirm what can be supplied for that project.

Section through a thermally broken aluminium window profile with insulating glass
45 dB Catalogue acoustic figure
Five criteria

Each figure needs a build-up behind it.

Wind load Project-specified
Air permeability Multi-line seal
Water tightness Seal + drainage
Acoustic 45 dB*
Thermal Thermal break + fill

* 45 dB is the catalogue acoustic figure for the relevant system, measured under laboratory conditions. Site performance depends on the installed build-up. The bars indicate design emphasis only; they are not test grades.

02 / Build-up

Take the performance apart, layer by layer.

Configuration changes with the system and the project. The table explains the options; it is not a fixed data sheet.

One system can deliver different performance: from a standard insulating unit to laminated Low-E glass, from two seal lines to a full multi-line seal, from a basic multi-point lock to a reinforced locking set. Before quoting, we put the configuration in writing so “built to a high standard” never becomes the specification.

Where needed, we work back from the wind and thermal requirements of your market, then issue the matching shop drawings and opening schedule.

Profile6063-T5 aluminium, thermally broken
Wall thicknessAs approved on the shop drawing and the destination market requirement
Thermal breakPA66 GF25 strip, optional foam fill
GlazingInsulating; laminated, Low-E, tinted or frosted as specified
HardwareMulti-point locking, concealed hinges or rollers from qualified suppliers
SealingEPDM gaskets, multiple seal lines, drained and vented sill
FinishPowder coating, anodising, PVDF or porcelain finish
Installation interfaceSill, reveal and fixing details issued with the shop drawing
03 / Quality control

Six checks, not one last look.

Each stage is checked before the next one starts; a non-conforming part does not move forward.

01 Incoming inspection

Alloy, temper, wall thickness, finish and glass batch are checked against the order before release to the line.

02 Profile machining

Cut length, end square, machining positions and corner crimping are checked at the bench.

03 Insulating glass

Spacer bend, desiccant fill, butyl and secondary sealant are inspected on each unit before pressing.

04 Window assembly

Hardware, gaskets, glazing and operation are checked on every leaf.

05 Performance sampling

Air, water and operation are sampled at the agreed frequency; project-specific testing is arranged separately where required.

06 Pre-packing final check

Size, colour, glass, hardware, label and quantity are checked against the packing list.

04 / Export compliance

We do not display certificates we do not hold.

Markets test differently, and a certificate applies to a specific model and build-up. Confirm the scope before relying on it.

We can provide material declarations, glass reports and hardware data for a project. Where the project requires it, we can arrange testing to the relevant standard at a recognised laboratory. Certificates are issued by the laboratory for a specific model; cost and lead time are confirmed per project.

This site does not display CE, UL, NFRC, SABER or AS marks unless the corresponding certificate has been obtained for the model and can be supplied.

If the test standard is fixed at drawing stage, send the standard reference, the size to be tested and who carries the cost. We will quote a workable route against it.

Enquiry

Request the spec sheet for your market

Send the market and the standard you build to. We will reply with the configuration and the documents we can provide.

Enquiry received

We have recorded your request and will reply within one working day.

WhatsApp